Intelligence 2014 R2 Patch 01 (v.2.0.001)

Материал из archestra.info
Перейти к: навигация, поиск

Wonderware Intelligence 2014 R2 Patch 01 (v.2.0.001) Readme

Last revision: 7/20/2015

About This Readme

This document contains important information about Wonderware® Intelligence 2014 R2 Patch 01 (v.2.0.001). The Patch 01 Readme updates the previous ReadMe file included with Wonderware Intelligence 2014 R2. The entire Wonderware Intelligence 2014 R2 Readme is included in this document, following the Patch 01 sections.

Use the following links to navigate to the various sections of the Patch 01 Readme: 

About this Release

Wonderware Intelligence 2014 R2 P01 (v.2.0.001) contains the following enhancements:

  • Support for SQL Server stored procedures in custom queries
  • Support for Intelligence keywords that dynamically represent a start time and end time in custom queries
  • Support for the latest version of Microsoft SQL Server:
    • Microsoft SQL Server 2014/ SP1 Standard 64-bit (x64)
    • Microsoft SQL Server 2014/ SP1 Enterprise 64-bit (x64)
    • Microsoft SQL Server 2012 SP1/SP2 Standard 64-Bit (x64)
    • Microsoft SQL Server 2012 SP1/SP2 Enterprise 64-Bit (x64)

For information on how to use the custom query enhancements, see the "Data Sources" chapter in the Wonderware Intelligence Administration Guide.

< top of document >

Product Compatibility

Wonderware Intelligence software 2014 R2 P01 (v.2.0.001) is compatible and can co-exist with the following products:

Component Version Compatibility Co-existence
Wonderware® System Platform
2014, 2014 P01, 2014 R2, 2014 R2 P01 Yes* Yes
ArchestrA® System Platform
2012 R2, 2012 R2 P01, 2012 R2 P02 Yes Yes
Wonderware® Manufacturing Execution System 2014 and 2014 SP1 Yes Yes
Wonderware® InBatch
2014 R2 (10.2) Yes
2014 (10.1) Yes Yes
Wonderware Recipe Manager Plus 2014 R2 (2.0) Yes No
SCADAlarm 6.0 SP2 P01 No No
Wonderware® Historian Client 10.1 or greater N/A Yes
Wonderware® Historian Server 2012 R2 P02, 2014 P01, 2014 R2 Yes* Yes
ArchestrA® Workflow 2012 R2 SP1 N/A No
Wonderware® Skelta BPM 2014 R2 Yes Yes

*Note: For the Historian Data Adapter compatibility with Historian 2012 R2, the Hot Fix CR L00136281 is needed on the Historian Server machine and for compatibility with Historian 2014 P01, the Hot Fix CR L00136283 is required. Contact your distributor or the Wonderware Technical Support to obtain these hot fixes.

< top of document >

Patch 01 Installation

Follow these steps to install patch 01:

  1. Back up the Intelligence database before you start the patch installation.
  2. Undeploy the Intelligence DataSource, Dimension, and Measure objects. Do the following:
    1. Open the ArchestrA IDE on the computer that has Intelligence 2014 R2 installed and where the Intelligence objects are configured.
    2. Right-click on the Galaxy and click Undeploy in the shortcut menu. In the message box that appears, click No to keep the existing data.
    3. In the Deployment view, expand the nagivation tree to verify that all Intelligence objects have been un-deployed successfully.
    4. Close the ArchestrA IDE.
  3. Install the patch files and reconfigure the Wonderware Intelligence Server and Wonderware Data Adapter features. Do the following:
    1. Run Intelligence2014R2Patch01.exe to start the patch installation program.
    2. In the EULA screen, accept the license agreement, and then click Next.
    3. In the feature selection screen, make sure that Wonderware Intelligence 2014 R2 P01-(xxbit) is selected (where xx is 64 or 32, depending on your operating system), and then click Install.
    4. You are prompted to stop the running Intelligence services. Open the Microsoft Windows Services utility and stop the Wonderware Intelligence service and the Wonderware Intelligence DA service. The Wonderware Intelligence DA service may take a few extra seconds to completely stop, even if is shown as stopped.
    5. In the patch installation program, click Install again to continue the installation.
    6. After the installation completes, click Finish. The Configurator opens.
    7. Reconfigure the Wonderware Intelligence Server and Wonderware Data Adapter features.
    8. Close the Configurator.
    9. When prompted, restart the computer.
  4. After the computer restarts, import the updated Intelligence objects and redeploy them. Do the following:
    1. Open the ArchestrA IDE.
    2. On the Galaxy menu, point to Import, and then click Objects. The Import Automation Object(s) dialog box appears.
    3. Open the IntelligenceObjects.aaPKG file located in the following folder: (C:\Program Files (x86)\Wonderware\Intelligence\AppObjects).

      NOTE: Your path may be different, depending on your operating system.

    4. In the Import Preferences dialog box, accept the default settings, and then click OK.
    5. Redeploy the Intelligence objects. The message box appears.
    6. Click No to keep the existing data.

< top of document >

Resolved Issue

This section describes an important resolved issue in Wonderware Intelligence 2014 R2 P01 (v.2.0.001). The following list is not a comprehensive list of all resolved issues.

L00136962: HF CR L0013811 SR 52310442: An issue occurs if the Intelligence Server user does not have sysadmin permissions. The following error may appear in the ArchestrA Logger: "System.Data.SqlClient.SqlException (0x80131904): An error occurred in the Microsoft .NET Framework while trying to load assembly id 65536. The server may be running out of resources, or the assembly may not be trusted with PERMISSION_SET = EXTERNAL_ACCESS or UNSAFE. Run the query again, or check documentation to see how to solve the assembly trust issues."

With this patch, the user account of the Wonderware Intelligence service is no longer required to be a member of the SQL Server sysadmin fixed server role. As long as the same user account is not shared by other software that requires being a member of the sysadmin fixed server role, the membership of this role can be removed after the patch has been completely installed and configured.

< top of document >

Wonderware Intelligence 2014 R2 (v.2.0) Readme

Last revision: 04/22/2015

About This Readme

This document contains important information about Wonderware® Intelligence 2014 R2 (v.2.0). Review this document for Product enhancements and new features, system requirements and compatibility, resolved issues and known issues in this version and changes, if any, to the Intelligence software documentation included on this CD.

Use the following links to navigate to the various sections of this Readme: 

About this Release

With the release of Wonderware Intelligence 2014 R2 (v.2.0), the following list of new features and enhancements are introduced.

  • The Intelligence Measure tables are now populated in a 'Reversed Backfill' manner, i.e., the measure will start processing current data in the ‘forward’ direction and older data will fill in from current time until it reaches the configured backfill date. This allows the end user to have current data visibility immediately, while the backfill proceeds in parallel.
  • Support for common Reporting infrastructure. This infrastructure relies on the Intelligence Services and Data Store to deliver a central reporting database that can be used by reporting, dashboard, and analysis tools. This reporting framework provides a utility called Intelligence Model Deployment that allows you to deploy a predefined Intelligence Model delivered by other products such as Wonderware MES. In this scenario the ArchestrA IDE is not required to build and deploy an Intelligence Model. This model currently supports only one data source but can have one or more dimensions, and zero or more measures.
  • When measures are updated, the rows affected by the "Update" period are calculated and stored in a temporary table. The data store is updated only when all calculations are ready. This drastically reduces the amount of time during which current data is unavailable in the data store.
  • Direct connectivity of Tableau software to the underlying data sources of the Intelligence model. For example, if the Intelligence Model uses Wonderware MES as a data source, the Analytics Client and Dashboard Server may connect directly to the MES database for viewing detailed data from the MES database (typical drill-down scenario). Direct access to data sources not used in the Intelligence Model is a violation of the license agreement.
  • Upon certain changes to the configuration of a measure (for example, the addition of a calculation), you can now keep the data already accrued in the measure table (assuming you click "No" when prompted to remove data when you deploy/undeploy the measure). The system will then add a column to the measure table for the new calculation and populate that column with data from the time of deployment (no backfill of data for the newly added calculation).
  • You can now optionally disable the majority of non-clustered indexes on measure tables, allowing for faster backfilling and reduced disk space usage. Once backfill is completed, you can selectively re-enable the indexes that will help your client applications. For more information, see Advanced Performance Settings in the Wonderware Intelligence Administration Guide.
  • New look and feel of the installer and the Configurator Utility to enhance the user experience.
  • Support for 64-bit server operating systems only. This results in major performance improvements which allows faster processing of dimensions and measures.
  • Improved security features to reduce cyber vulnerabilities.
  • This version of Wonderware Intelligence leverages the new Schneider Electric Licensing system to provide a simplified license management experience.

Deprecated Feature

The following features are now deprecated in Wonderware Intelligence 2014 R2 (v.2.0).

  • Intelligence Client
  • The OSISoft PI Server data adapter is not delivered in this release. As such upgrades of models from prior versions of Wonderware Intelligence to Wonderware Intelligence 2014 R2 (v.2.0) are not supported. Please contact Schneider Electric Software Product Marketing if you plan to use the OSISoft PI Server data adapter.

< top of document >

System Requirements

This section describes the hardware, software, and operating system requirements to install the Wonderware Intelligence software.


Hardware Requirements

The following are the hardware requirements to install the Wonderware Intelligence software:

  • 32 or 64 bit processors. Note: 64 bit processors is required only for Server components.
  • Fast (100 Mbit or faster) and reliable network connection to external software systems.

The following table lists the hardware requirements for the Wonderware Intelligence Server and Intelligence Analytics Client:

Intelligence Component Requirements Processor Memory (RAM) Available Disk Space System Network Connection
Intelligence Server Minimum 3 GHz or greater, 64 bit only 4 GB or greater 50 GB to 500 GB, depending on quantity of data being aggregated Server class system -
Intelligence Run-time Server Recommended 3 GHz or greater (Quad processor), 64 bit only 16 GB or greater 100 GB, depending on quantity of data being aggregated Server class system -
Intelligence Database Recommended 3 GHz or greater (Quad processor), 64 bit only 8 GB or greater 500 GB, depending on quantity of data being aggregated Server class system -
Intelligence Data Adapter Service Recommended 3 GHz or greater, 64 bit only 2 GB or greater 100 MB - 10/100 Mbps or greater connection to the Intelligence Server and data source systems
Intelligence Analytics Client Minimum Pentium 4 or AMD Opteron or greater 2 GB or greater 250 MB - -

Operating System Requirements

The following table lists the supported operating systems for Wonderware Intelligence Server. The requirements for a remote data adapter are the same as for a Wonderware Intelligence Server.

Operating System Edition Service Pack Bit Version Wonderware Intelligence Server or Remote Data Adapter Wonderware Intelligence Model Deployment
Windows Server 2008 R2 Standard, Enterprise SP1 64-bit (x64) Supported Supported
Windows Server 2012 Standard, Datacenter none 64-bit (x64) Supported Supported
Windows Server 2012 R2 Standard, Datacenter none 64-bit (x64) Supported Supported







Support for Non-English Versions of Operating Systems

The English version of the Wonderware Intelligence software runs on the following non-English operating systems:

  • French
  • German
  • Japanese
  • Simplified Chinese

Software Requirements

The following are the Wonderware and other third-party software requirements to install or use the Wonderware Intelligence software:

  • Microsoft SQL Server (may be on a separate computer from the Intelligence Server). For more information, see Microsoft SQL Server Requirements.
  • Microsoft .NET Framework and CLR 4.5.1. (Will be installed during the installation if needed)
  • ArchestrA Integrated Development Environment (IDE) 2012 R2 P02 or greater (may be on a separate computer from the Intelligence Server).

The following are third-party software that are required for the various data adapters of the Wonderware Intelligence software:

  • Depending on the Operating System, Microsoft.ACE.OLEDB.12.0 is required on the data adapter service node if you plan to use the text file data adapter.

    For example: If the Operating system is x64 bit then user needs to install x64 bit Microsoft.ACE.OLEDB.12.0 drivers and if the Operating system is x32 bit then user needs to install x32 bit Microsoft.ACE.OLEDB.12.0 drivers.

  • Client components of Oracle 11g and 12c on the node on which the Data Adapter Service is installed, if used as a data source.
  • Microsoft SQL Server 2005 SP3 or later if used as a data source. Note that Microsoft SQL Server 2005 is not supported for the Intelligence Server.

    Note: The OSISoft PI Server data adapter has not yet been validated for Wonderware Intelligence 2014 R2 (v.2.0) on 64-bit platforms. Please contact Wonderware product marketing (product.marketing@invensys.com) if your application requires an OSISoft PI Server data adapter.

Microsoft SQL Server Requirements

The following versions of Microsoft SQL Server are supported:

  • Microsoft SQL Server 2008 R2 SP1/SP2 Standard 32-Bit (x86) or 64-Bit (x64)
  • Microsoft SQL Server 2008 R2 SP1/SP2 Enterprise 32-Bit (x86) or 64-Bit (x64)
  • Microsoft SQL Server 2012 SP1 Standard 64-Bit (x64)
  • Microsoft SQL Server 2012 SP1 Enterprise 64-Bit (x64)
  • Microsoft SQL Server 2014 Standard 64-bit (x64)
  • Microsoft SQL Server 2014 Enterprise 64-bit (x64)

Additional notes:

  • The SQL Server language must be the same as the operating system language. For example, you can only run the French version of SQL Server on the French version of the operating system. You can, however, have a UK English operating system and a US English SQL Server, and vice versa.
  • The SQL Server collation settings must be compatible with the operating system version. Having different language versions of the operating system and the SQL Server collation is not supported. Note that the default SQL Server database collation setting is sensitive to the regional settings (such as the date/time format). Important Note: SQL Server should be installed after the regional settings have been set.
  • A named instance of SQL Server is supported.
  • Microsoft SQL Server fail-over clustering is supported.
  • A case-sensitive SQL Server is not supported (data store only).
  • SQL Server Express is not supported.
  • The following Microsoft SQL Server components have to be installed on the Wonderware Intelligence Server node, if the data store is on a node other than the Wonderware Intelligence Server:
    • Client Tools Connectivity
    • Client Tools Backwards Compatibility
    • Management Tools – Basic

< top of document >

Upgrading to Wonderware Intelligence 2014 R2 (v.2.0)

Upgrading Wonderware Intelligence installs 2014 R2 (v.2.0) on a computer that has a previous version currently installed.

Note: Wonderware Intelligence 2014 R2 (v.2.0) supports upgrade from Wonderware Intelligence 2012 (v.1.5 SP1) only. We recommend to back up your Wonderware Intelligence database and export your model configuration before to proceed with your system upgrade.

The following high level steps for upgrade are mentioned for your reference. However, it is imperative that you must refer to the Upgrade section of the Wonderware Intelligence Installation Guide for further details.

  1. Undeploy your Wonderware Intelligence model (with the option to keep the data).
  2. Run the setup.exe from the CD image.
  3. Follow the instructions as the installation progresses.
  4. On completion of the file upgrade, click Configure.
  5. Once the Configurator utility is displayed, reconfigure BOTH the Intelligence Server and Data Adapter services (even if they appear as already configured).
  6. Close the Configurator.
  7. Reboot the system (even if not prompted to do so).
  8. Open the ArchestrA IDE.
  9. Import the new Wonderware Intelligence objects (located in the AppObjects folder of your Intelligence installation path).
  10. Close the IDE.
  11. From the Windows Service console, restart the ArchetrA Galaxy Repository service.
  12. From the Windows Service console, restart the Wonderware Intelligence services (including Data Adapter).
  13. Open the IDE.
  14. Verify the Data Source objects by testing the Data Source connection, perform a ‘Get Schema’ and then save (for each of your data source objects).
  15. ‘Validate’ the Dimension and Measure objects, resolve any reported warning or error.
  16. Deploy the model.

Note: The Schneider Electric Licensing Server component is not installed as a part of an upgrade and if a local license server is required, you must install and configure the Schneider Electric Licensing Server component after the upgrade using the installation Modify option. If you are using a remote license server, then configure the Schneider Electric License Server to point to the remote node in the Configurator utility.

< top of document >

Product Compatibility

Wonderware Intelligence software 2014 R2 (v.2.0) is compatible and can co-exist with the following products:

Component Version Compatibility Co-existence
Wonderware® System Platform
2014 or 2014 R2 Yes* Yes
ArchestrA® System Platform
2012 R2 Yes Yes
Wonderware® InTouch® 10.5 Yes Yes
11 Yes Yes
Wonderware® Manufacturing Execution System 2014 and 2014 SP1 Yes Yes
Wonderware® InBatch
2014 R2 (10.2) Yes No
2014 (10.1) Yes No
SCADAlarm 6.0 SP2 P01 No No
Wonderware® Historian Client 10.1 or greater N/A Yes
Wonderware® Historian Server 2012 R2 P02, 2014 P01, 2014 R2 Yes* Yes
ArchestrA® Workflow 2014 N/A Yes

*Note: For the Historian Data Adapter compatibility with Historian 2012 R2, the Hot Fix CR L00136281 is needed on the Historian Server machine and for compatibility with Historian 2014 P01, the Hot Fix CR L00136283 is required. Contact your distributor or the Wonderware Technical Support to obtain these hot fixes.

< top of document >

Licensing

Wonderware Intelligence Licensing

This release of Wonderware Intelligence enforces licensing through the new Schneider Electric Licensing system.

For more information regarding the Licensing of Wonderware Intelligence, see the Schneider Electric License Server Guide available at the following location in the system where Schneider Electric Licensing is installed: All Programs -> Schneider Electric -> Schneider Electric License Manager User Guide.

Tableau Component Licensing

The Analytics Client (Tableau Desktop) and Dashboard Server (Tableau Server) versions shipped with Wonderware Intelligence are allowed to access data only from the Wonderware Intelligence data store and data sources used in the Intelligence model (Drill-down scenario for example). Using the Analytics Client outside of those boundaries is a violation of the license agreement.

The Wonderware Intelligence software enforces licensing for the Analytics Client through license keys provided by Wonderware, on your license certificate. When you first start the Analytics Client, a software activation window prompts you to enter the license key. The same applies for the Dashboard Server.

< top of document >

Resolved Issues

This section describes important resolved issues. The following list is not a comprehensive list of all resolved issues.

L00131010: HF CR L00130481: Issue related to the SQL Server running out of pooled connections is resolved by adding new configuration setting that enables the customer to specify the maximum pool size for database connections.
L00131054: HF CR L00130376: Measure is processed and recorded for the entire shift period, instead of scheduled time slice. This issue is fixed.
L00133450: HF CR L00131490: Measure backfills returns a timeout error after a certain amount of data has already been backfilled.
L00129165: HF CR L00128553: Timeout encountered while deploying large number of measures or dimensions.
L00121506: HF CR L00120757: Advanced calculation editor is fixed and allows mapping to a dimension in context.
L00121065: HF CR L00120920: The execution of stored procedure "sp_CompareDimensionRecords" throws the following error: System.Data.SqlClient.SqlException (0x80131904): Timeout expired. The timeout period elapsed prior to completion of the operation or the server is not responding.
L00122672: HF CR L00119135: Modification of a measure configuration, specifically calculations can result in deletion of all data in the measure table.
L00127599: HF CR L00120638: Pre-requisite validation for SQL connectivity to the Database results in error as it validates the presence of the MS-SQL 2008 client only.

< top of document >

Known Issues

L00102948: If you import a model using .csv, and the model includes dimensions that have filters, the objects will be in an error state after you validate them.

To work around this issue, open the Dimension object, go to the Filter tab, slightly modify the filter expression (for example, add a space at the end), and then validate the expression. After you save and check in the object, the object will no longer be in an error state.

L00108588: Measure records will get a valid context reference only when both the dimension key field's data type and measure source field's data type in the measure relation are the same. If they are not of the same data type, then 0 (meaning no matching record found) is assigned as the context reference for the measure record. This issue mainly occurs when you are using any numeric data type as a key dimension field.
L00109411: A data source custom query must not include an ORDER BY clause in the syntax. Although the validation and data preview succeed, data will not be processed at run time.
L00110814: If you attempt to view a custom query in an instance of a DataSource object in the ArchestrA IDE version 3.1 SP3 or later, the IDE stops responding. To work around this issue, view the custom query in the object template, not the instance.
L00114494: If you undeploy an object too quickly after you deploy it, you may get a run-time error. Wait for the initial execution to finish (you will see the data in the corresponding measure table) and then try undeploying again.
L00115066: When you change only the priority of a source data item using the Select Source Data Items dialog box for a dimension, the object is not marked as updated. Even after you redeploy the object, the old configuration is retained. Make sure that you have performed some other configuration (for example, edit the description) so that the asterisk appears next to the object name and you are prompted to save the object.
L00115753: If you lock the Data Adapter Type list in a DataSource object derived template, changes to the available adapter list performed at the derived template level are not propagated to the instance object. Because the DataAdapterTypes attribute contains an incorrect list, this causes errors if you set/retrieve the DataAdapterType attribute for the instance object. To work around this issue, do not lock the Data Adapter Type list.
L00135838: Wonderware Intelligence 2014 R2 (v.2.0) does not support DateTime2 SQL Server data types. The workaround is to cast Datetime2 to Datetime. For more information, see https://msdn.microsoft.com/en-us/library/bb677335.aspx.
L00136275: If you connect to an incorrect Wonderware Historian in the Data Source and then try to connect to the correct Wonderware Historian, the logger continuously logs warning messages that it is still unable to connect to the incorrect Historian.

Workaround: You must restart the Wonderware Intelligence Data Adapter service to stop the warning messages in the SMC logger.

L00136325: If a measure is undeployed while it is busy processing calculation, the following errors/warnings will be returned in the SMC logger: "ExecuteMeasureBackfill() failed unexpectedly. Retry measure backfill Measure [name of measure]." You can ignore these messages.
L00136408: When you import a model in ArchestrA IDE set on a different Operating System language than the original creation language, the Data Source time zone is not set properly and can cause issues during model deployment.

Workaround: After importing the model, make sure to remap the Data Source(s) time zone in the Connection tab of the Data Source object.

Software Documentation

The Wonderware Intelligence software documentation set includes the following:

  • Wonderware Intelligence Software Installation Guide - Provides information about installing and configuring the Wonderware Intelligence software features.
  • Wonderware Intelligence Administration Guide - Provides information about configuring and mapping of various data sources; managing Intelligence objects such as dimension, measures, datasource, and their deployment; and security.
  • Wonderware Intelligence Model Deployment Guide - Provides information about using the Wonderware Intelligence Model Deployment utility.
  • Object Help - Provides information about run-time behavior, configuration, and run-time attributes of the Dimension, Measure, and the DataSource objects.
  • ReadMe (This document) - Provides information about software and hardware requirements, known issues, licensing, and documentation.

The Wonderware Intelligence product library consists of a set of Portable Document Files (PDF) located in the UserDocs folder of the Wonderware Intelligence software installation CD. You need Adobe Reader installed on your computer to view the Wonderware Intelligence software documentation. You can download the latest version of Adobe Reader from the Adobe Corporation web site:

http://www.adobe.com/products/reader.html



After installing Adobe Reader, double-click on a PDF file to view the book with Adobe Reader. You can also open a book with the Adobe Reader Open command from the File menu.

The Wonderware Intelligence software installation instructions are located in the root folder of the Wonderware Intelligence software installation CD as an online Help file. You can view these instructions by clicking Help as you start the Wonderware Intelligence software installation procedure.

< top of document >